分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: A fully digital beam position monitoring system (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As analog-to-digital converter (ADC) is a crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. Different sampling modes were used and compared through tests. Long term variation among four sampling channels, which would introduce errors in beam position measurement, is studied, too. An interleaved distribution scheme was designed to address this issue. To evaluate the sampling methods, in-beam tests were conducted in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn (TBT) position resolution better than 1 m is achieved, and the slow-acquisition (SA) position resolution is improved from 4.28 m to 0.17 m.
分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: Commercial off-the-shelf (COTS) ADCs (analog-to-digital converters) that are radiation-tolerant, high speed, high density and low power will be used in upgrading the LAr (liquid argon) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) of the COTS ADCs should be characterized. In our initial TID test, 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting requirements of the FE electronics were checked, and the ADS5272 of Texas Instruments (TI) was the best performer of all. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest of all the 17 candidates. Based on the TID performance, we designed an SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).
分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: The Dark Matter Particle Explorer (DAMPE) is being constructed as a scientific satellite to observe high energy cosmic rays in space. As a crucial detector of DAMPE, the BGO calorimeter consists of 1848 PMT dynode signals which bring difficulties in front-end electronics on the space-limited and power-limited satellite platform. To overcome the challenge, a low-noise, low-power and high-integration ASIC chip, named VA32HDR14.2, is taken into account. In order to evaluate the radiation tolerance of the chip in space radiation environment, both single event effect (SEE) and total ionizing dose (TID) tests were performed. The SEE test result shows that the effective linear energy transfer (LET) threshold of single event latch-up (SEL) of the chip is around 23.0 MeV-cm2/mg, which is relatively sensitive, thus protection methods must be taken in the electronics design. The TID test result shows that the TID performance of the chip is higher than 25 Krad(Si), which satisfies the design specification.
分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: High precision time measurement is required in the readout of the neutron wall and TOF walls in the external target experiment of the Cooling Storage Ring (CSR) project in the Heavy Ion Research Facility in Lanzhou (HIRFL). Considering the time walk correction, both time and charge are measured in the readout electronics. In this 16-channel measurement module, time and charge information are digitized by TDCs at the same time based on the Time-Over-Threshold (TOT) method; meanwhile, by employing high-density ASIC chips, the electronics complexity is effectively reduced. Test results indicate that this module achieves a time resolution better than 25 ps and a charge resolution better than 5% over the input amplitude range from 50 mV to 3 V.