您当前的位置: > 详细浏览

Dose rate distribution of photoneutrons in an ID beamline of SSRF: simulations and measurements

请选择邀稿期刊:
摘要: Photoneutrons, emitted by means of photonuclear interactions when gas bremsstrahlung interacts with beamline components, can be another potential radiation source needed to be considered for shielding design and dose assessment of beamline. In this paper, simulations and measurements of photoneutrons dose rate at beamline BL09U are carried out when Shanghai Synchrotron Radiation Facility (SSRF) running at Top-up mode (3.5 GeV, 235 mA). A geometry model is constructed for the beamline BL09U with considerations of the scattering process of the major optical components. The model is compiled into Monte Carlo simulation code FLUKA to calculate photoneutron dose distribution. Measurements of the photoneutrons dose rate were performed by using Environmental Neutron Monitor (ENM). Observation points were arranged uniformly along the inside and outside of the optical enclosure (OE) of BL09U. The calculation results agree with experiments within the measurements uncertainties. It is verified that photoneutrons dose simulation is reliable. The simulation and measurement methods can be applied to evaluate the neutron dose level of other beamline stations, and provide references for the shielding design of the beamlines at SSRF in the near future.

版本历史

[V1] 2023-06-18 17:37:39 ChinaXiv:202306.00461V1 下载全文
点击下载全文
预览
许可声明
metrics指标
  •  点击量338
  •  下载量142
评论