分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: Direct demodulation method (DDM) was applied to reconstruct -ray spectra. Boosted Richardson-Lucy iteration was introduced into DDM. Monte Carlo method (here GEANT 4) was proposed to calibrate response function and establish response matrix. First, gauss function was regarded as total energy peak. Spectra line was simulated with nine gauss functions. And afterwards DDM was applied to reconstruct the simulated spectra line and determine peak positions and areas. Compared with original spectra, for case that peak position interval was about 1/3 full width half maximum (FWHM), the error of rebuilding peak position was 2 channels. The rest of peaks could be searched accurately. The relative errors of all peaks area were less than 4%. Then, three key factors, including noise, background, response matrix, were discussed. Finally, DDM was applied to calibrate the field NaI gamma spectrometer. The errors of U, Th, K were less than 5%. Comprehensive studies have shown that it is feasible to reconstruct gamma-ray spectra with DDM. DDM can significantly pseudo-improve energy resolution of gamma spectrometer, effectively decompose doublets whose peak potential interval is 1/3 FHWM, and accurately search peak and calculate areas. DDM can restrain noise strongly but is greatly influenced by background. And DDM can improve the accuracy of qualitative and quantitative analysis in combination with the conventional spectrum analysis method.
分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: In energy dispersive X-ray fiuorescence (EDXRF), quantitative elemental content analysis becomes difficult due to the existence of the noise, the spectrum peak superposition, element matrix effect, etc. In this paper, a hybrid approach of genetic algorithm (GA) and back propagation (BP) neural network is proposed without considering the complex relationship between the elemental content and peak intensity. The aim of GA-optimized BP is to get better network initial weights and thresholds. The starting point of this approach is that the reciprocal of the mean square error of the initialization BP neural network is set as the fitness value of the individuals in GA; and the initial weights and thresholds are replaced by individuals, then the optimal individual is searched by selecting, crossover and mutation operations, finally a new BP neural network model is established with the optimal initial weights and thresholds. The quantitative analysis results of titanium and iron contents in five types of mineral samples show that the relative errors of 76.7% samples are below 2%, compared to chemical analysis data, which demonstrates the effectiveness of the proposed method.
分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: Dielectric wall accelerator (DWA), towards high gradient acceleration field (30 MeV/m100 MeV/m), is under development at Institute of Modern Physics. A prototype was designed and constructed to prove the principle. This needs a short pulse high current electron source to match the acceleration field generated by the Blumlein-type pulse forming lines (PFLs). In this paper, we report the design and test of a new type short pulse high current electron gun based on principle of vacuum arc discharge. Electron beams of 100 mA with pulse width of 10 ns were obtained.
分类: 物理学 >> 核物理学 提交时间: 2016-08-31
摘要: A new hybrid experiment has been constructed to measure the chemical composition of cosmic rays around the "knee" in the wide energy range by the Tibet ASγ collaboration at Tibet, China, since 2014. They consist of a high-energy air-shower-core array (YAC-II), a high-density air-shower array (Tibet-III) and a large underground water-Cherenkov muon-detector array (MD). In order to obtain the primary proton, helium and iron spectra and their "knee" positions in the energy range lower than 1016 eV, each of PMTs equipped to the MD cell is required to measure the number of photons capable of covering a wide dynamic range of 100 - 106 photoelectrons (PEs) according to Monte Carlo simulations. In this paper, we firstly compare the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu. This is the first comparison between R5912-PMT and CR365-PMT. If there exists no serious difference, we will then add two 8-inch-in-diameter PMTs to meet our requirements in each MD cell, which are responsible for the range of 100 - 10000 PEs and 2000 - 1000000 PEs, respectively. That is, MD cell is expected to be able to measure the number of muons over 6 orders of magnitude.