• Analysis of fixation method of fuel assembly for lead-alloy cooled reactor

    分类: 核科学技术 >> 裂变堆工程技术 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: As a potential candidate for generation IV reactors, lead-alloy cooled reactor has attracted much attentions in recent years. The China LEAd-based research Reactor (CLEAR) is proposed as the primary choice for the accelerator driven subcritical system project launched by Chinese Academy of Sciences. Lead-bismuth eutectic (LBE) is selected as the coolant of CLEAR owing to its efficient heat conductivity properties and high production rate of neutrons. In order to compensate the buoyancy due to the high density of lead-alloy, fixation methods of fuel assembly (FA) have become a research hotspot worldwide. In this paper, we report an integrated system of ballast and fuel element for CLEAR FA. It guarantees the correct positioning of each FA in normal and refueling operations. Force calculation and temperature analysis prove that the FA will be stable and safe under CLEAR operation conditions.

  • A method for direct conversion of EPID images to incident fluence for dose reconstruction

    分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: A direct incident fluence measurement method based on amorphous silicon electronic portal imaging device (a-Si EPID) has been developed for pretreatment verification of intensity-modulated radiation therapy (IMRT). The EPID-based incident fluence conversion method deconvolves EPID images to the primary response distribution based on measured lateral scatter kernels in the EPID detector using Conjugate Gradient algorithm. The primary response is converted to the incident fluence based on measured fluence conversion matrix which corrects for off-axis position dependence of the a-Si EPID response and the horn beam profile caused by flatting filter. To verify feasibility and accuracy of this method, square fields of various sizes and two IMRT plans were delivered. The dose distributions computed based on EPID-derived incident fluence were compared with the measurement data. For all square field sizes except the smallest field (2 cm), the mean dose differences in cross-line dose profiles were within 1% excluding the penumbra region, and gamma passing percentages with a 2%/2 mm criterion were about 99%. For two IMRT plans, the least gamma passing percentage for all eight IMRT fields was 98.14% with 2%/3 mm criteria. It can be concluded that our direct EPID-based incident fluence conversion method is accurate and capable of being applied to pretreatment dose verification in clinical routines.

  • An improved method for analyzing the output stability of medical LINAC based on planar dose

    分类: 核科学技术 >> 粒子加速器 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: The absolute dose difference of the iso-center position at different times was used to evaluate the stability of medical linear accelerator (LINAC). In order to eliminate the drawback of point dose without statistical significance and to investigate the output stability of segment with small weight related to intensity-modulated radiotherapy (IMRT), a modified method of evaluating the stability of LINAC was proposed based on planar dose combined with gamma method. With a commercial available two-dimensional ionization chamber, a set of planar doses with dose gradient from 2 cGy to 100 cGy were obtained. Then the gamma method was adopted to analyze the dose difference between the reference data and the evaluated data at each dose level. The results showed that the improved method based on planar dose for analyzing the output stability of the medical LINAC was feasible and efficient, and suggested that the reverse optimization should be aborted in clinical when the segment weight related to IMRT was under 10 MU.

  • Radiotherapy reliability analysis based on PSA method

    分类: 物理学 >> 核物理学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: The reliability of radiotherapy was evaluated and effective approaches were obtained in order to improve radiotherapy quality by using the Probabilistic Safety Assessment (PSA) method. This study investigated the feasibility of the PSA method being applied to radiotherapy through Image-guided Radiotherapy (IGRT) and chest tumor irradiation. A fault tree has been constructed after analyzing causal relationship of the events. After calculating RiskA, a total inaccuracy radiotherapy probability and the importance of all base events were obtained. The probability of inaccurate radiotherapy was 2.87%. Under the condition that the target delineation was perfectly right, the accuracy of radiotherapy significantly improved. With the calculation without Cone-beam Computed Tomography (CBCT) being corrected before irradiation, the accuracy significantly decreased. The most important events were connected with the human factor. Improving human technical level could enhance radiotherapy quality control efficiently.