Subjects: Nuclear Science and Technology >> Nuclear Detection Technology and Nuclear Electronics Subjects: Physics >> Nuclear Physics submitted time 2024-02-26
Abstract: Cosmic rays are used for the calibration of the Veto detector at ETF in HIRFL-CSR of the Cooling Storage
Ring of Heavy Ion Research Facility in Lanzhou(HIRFL-CSR). The work is divided into two parts: position calibration
and time calibration. The hit positions of particles are obtained by position calibration and an uniform standard of the
measurement of particle hit time in the Veto detector is built through time calibration. The information of position and
time of particles serves as important criteria for eliminating changed particle events that hit the neutron wall detector,
providing support for the realization of the physical objectives of the neutron wall detector. A 2.53 cm position resolution
and a 1.09 ns time resolution have been achieved in this paper.