分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》
摘要: Field Programmable Gate Array (FPGA), combined with ARM (Advanced RISC Machines) is increasingly employed in the portable data acquisition (DAQ) system for nuclear experiments to reduce the system volume and achieve powerful and multifunctional capacity. High-speed data transmission between FPGA and ARM is one of the most challenging issues for system implementation. In this paper, we propose a method to realize the high-speed data transmission by using the FPGA to acquire massive data from FEE (Front-end electronics) and send it to the ARM whilst the ARM to transmit the data to the remote computer through the TCP/IP protocol for later process. This paper mainly introduces the interface design of the high-speed transmission method between the FPGA and the ARM, the transmission logic of the FPGA, and the program design of the ARM. The theoretical research shows that the maximal transmission speed between the FPGA and the ARM through this way can reach 50 MB/s. In a realistic nuclear physics experiment, this portable DAQ system achieved 2.2 MB/s data acquisition speed.
分类: 物理学 >> 凝聚态:结构、力学和热性能 提交时间: 2017-03-26
摘要: Dislocations would be induced after plastic deformation, which might change the mechanical properties of solids. FeCrNi austenitic model alloy and its Mo-diluted alloy were cold rolled with different degree of thickness reduction. Positrons are sensitive to point defects, which are easily trapped and annihilated around the trapping sites. The mean positron lifetimes have been used to estimate the average dislocation concentration in solids. Meanwhile, the trapping efficiency μ was calculated from the lifetime results. The trapping efficiency value is estimated about 3.31×10-7 cm3s-1 for FeCrNi alloy and 3.31×10-7 cm3s-1 for Mo-diluted alloy, respectively. The increment of the hardness value during plastic deformation is related to the increase of the dislocation density and dislocation pile up in solids.
分类: 物理学 >> 凝聚态:结构、力学和热性能 提交时间: 2017-03-26
摘要: Solution annealed type 316L austenitic stainless steels were irradiated using 2 MeV Fe ions at room temperature. The implanted fluences were 2012 ions/cm2 and 1013 ions/cm2, respectively. Variable mono-energetic positron beam was performed to characterize the evolution of microstructure and irradiation induced defects. Results show that large amount of vacancy defects formed after heavy ion irradiation. In which, some of mono-vacancies might migrate to form small-sized clusters at room temperature. After irradiation, implanted Fe atoms mainly be interstitials atoms, but some Fe atoms might recombine with vacancies due to their high mobility, which could decrease the defect concentration, effectively.
分类: 物理学 >> 凝聚态:结构、力学和热性能 提交时间: 2017-03-26
摘要: The evolution of microstruture for Fe16.7Cr14.5Ni model alloy and 316 stainless steel irradiated with 140 keV He ions were studied by Positron annihilation spectroscopy. The fluences were 1016 and 5016 He ions/cm2. The irradiation temperature was room temperature and 573 K, respectively. The variation of S parameter-incident positron energy profile indicated that large amount of vacancy-type defects formed after He ion irradiation. Meanwhile, helium atoms deposited in bulk and certain amount of He-vacancy complexes were formed. The vacancy-type defects could be the major defects in track region and He-vacancy complexes would be the main defects in cascade region. The vacancy-type defects could migrate and aggregate to form vacancy clusters and even microvoids at elevated temperature irradiation. The diffusion mechanism of helium atoms might be changed at different irradiation temperature.
分类: 物理学 >> 凝聚态:结构、力学和热性能 提交时间: 2017-03-24
摘要: In order to study the microstructural evolution of the He+ irradiated FeCrNi model alloy, 140 keV He+ ions were implanted into the specimen with the fluence of 1015 ions/cm2 at room temperature. Positron Annihilation Spectroscopy was used to characterize the evolution of micro defects during isochronal annealing between 423 K and 873 K. The decrease of the S parameter between 573 K and 623 K has been associated to the annihilation of vacancy clusters, which were not trapped by helium atom. While the decline of the S parameter between 773 K and 823 K in the damage region might be caused by the dissociation of HenVm clusters. The dissociated vacancy clusters were unstable and annihilated rapidly, which decreases the concentration of vacancy defects.