• Effects of loading rate on root pullout performance of two plants in the eastern Loess Plateau, China

    分类: 生物学 >> 植物学 提交时间: 2023-10-17 合作期刊: 《干旱区科学》

    摘要: Root pullout performance of plants is an important mechanical basis for soil reinforcement by plant roots in the semi-arid areas. Studies have shown that it is affected by plant factors (species, ages, root geometry, etc.) and soil factors (soil types, soil moisture, soil bulk densities, etc.). However, the effects of loading rates on root pullout performance are not well studied. To explore the mechanical interactions under different loading rates, we conducted pullout tests on Medicago sativa L. and Hippophae rhamnoides L. roots under five loading rates, i.e., 5, 50, 100, 150, and 200 mm/min. In addition, tensile tests were conducted on the roots in diameters of 0.52.0 mm to compare the relationship between root tensile properties and root pullout properties. Results showed that two root failure modes, slippage and breakage, were observed during root pullout tests. All M. sativa roots were pulled out, while 72.2% of H. rhamnoides roots were broken. The maximum fracture diameter and fracture root length of H. rhamnoides were 1.22 mm and 7.44 cm under 100 mm/min loading rate, respectively. Root displacement values were 4.63% (0.43%) and 8.91% (0.52%) of the total root length for M. sativa and H. rhamnoides, respectively. The values of maximum pullout force were 14.6 (0.7) and 17.7 (1.8) N under 100 mm/min for M. sativa and H. rhamnoides, respectively. Values of the maximum pullout strength for M. sativa and H. rhamnoides were 38.38 (5.48) MPa under 150 mm/min and 12.47 (1.43) MPa under 100 mm/min, respectively. Root-soil friction coefficient under 100 mm/min was significantly larger than those under other loading rates for both the two species. Values of the maximum root pullout energy for M. sativa and H. rhamnoides were 87.83 (21.55) mmN under 100 mm/min and 173.53 (38.53) mmN under 200 mm/min, respectively. Root pullout force was significantly related to root diameter (P0.05). Root pullout strength was greater than root tensile strength for the two species. The results suggested that there was no need to deliberately control loading rate in root pullout tests in the semi-arid soil, and root pullout force and pullout strength could be better parameters for root reinforcement model compared with root tensile strength as root pullout force and pullout strength could more realistically reflect the working state of roots in the semi-arid soil.

  • Untangling the influence of soil moisture on root pullout property of alfafa plant

    分类: 地球科学 >> 地球科学史 提交时间: 2020-10-20 合作期刊: 《干旱区科学》

    摘要: Root pullout property of plants was of key importance to the soil reinforcement and the improvement of slope stability. To investigate the influence of soil moisture on root pullout resistance and failure modes in soil reinforcement process, we conducted pullout tests on alfalfa (Medicago sativa L.) roots at five levels (40, 30, 20, 10 and 6 kPa) of soil matric suction, corresponding to respectively 7.84%, 9.66%, 13.02%, 19.35% and 27.06% gravimetric soil moisture contents. Results showed that the maximal root pullout force of M. sativa decreased in a power function with increasing soil moisture content from 7.84% to 27.06%. Root slippage rate increased and breakage rate decreased with increasing soil moisture content. At 9.66% soil moisture content, root slippage rate and breakage rate was 56.41% and 43.58%, respectively. The threshold value of soil moisture content was about 9.00% for alfalfa roots in the loess soil. The maximal pullout force of M. sativa increased with root diameter in a power function. The threshold value of root diameter was 1.15 mm, because root slipping force was greater than root breaking force when diameter >1.15 mm, while diameter ≤1.15 mm, root slipping force tended to be less than root breaking force. No significant difference in pullout forces was observed between slipping roots and breaking roots when they had similar diameters. More easily obtained root tensile force (strength) is suggested to be used in root reinforcement models under the condition that the effect of root diameter is excluded as the pullout force of breaking roots measured in pullout tests is similar to the root tensile force obtained by tensile tests.